● Welding power: 3.5KW, 2.2KW only meet single-phase 220V voltage input;
● Optional accessories: S: S: scanner reading; G: GPS location; P: printer;
Note: The function realization of bar code scanning, print and GPS need to purchase the corresponding accessories.
◇ Advanced SCM control unit, abundant parameter setting, measuring and protecting function |
◇ High brightness LCD display, Chinese/English operation, friendly interface for human and machine |
◇ Wide power supply and voltage input, fully suitable for spot electric network wave |
◇ High accurate power, time controlling, ensure welding quality |
◇ Output response time fast(500??800ms), fine stability when power supply breaks |
◇ With function of 10 phases programmable welding, suitable for different welding requirement of fittings |
◇ Huge storage capacity for welding datum, easy way to enter welding parameters |
◇ Perfect design and SMT welding craftwork, Reduce fault of whole set |
◇ Protecting function against over-current, over-voltage and overload etc. |
◇ Compact design, small volume and light weight |
Working Range | 20-200mm |
Welding output voltage | 8-48V |
Single phase | 230V |
Power supply | 50-60Hz |
Max.absorbed power | 4000W |
Max.output current | 100A |
60%Duty cycle output | 60A |
Memory Capacity | 500 report |
Protection degree | IP 54 |
Dimensions machine (WxDxH) | 263X240X300mm |
Dimensions carrying case(WxDxH) | 352x188x341 |
Weight | 9Kg |
Key-press |
Name |
Function description |
OK |
Confirmation |
Confirm |
ESC |
Exit |
Cancel |
Ç |
Increase |
Menu up / Data increases |
È |
Decrease |
Menu down / Data decreases |
Æ |
Right shift |
Menu right shift/The modified position right shift |
Å |
Left shift |
Menu left shift/The modified position left shift |
Menu No. |
Name |
Range |
Default |
Keyboard attribute |
Parameter menu 1: welding parameters |
||||
1.01 |
Control mode selection | Constant voltage / constant current |
Constant voltage |
R/W |
1.02 |
Welding phases | 1~6 |
1 |
|
1.03 |
Pipe resistance | 0.00~19.99 |
0 |
|
1.04 |
Welding para. of 1st phase | 0~Rated |
0 |
|
1.05 |
Welding time of 1st phase | 0~9999 |
0 |
|
1.06 |
Welding para. of 2nd phase | 0~Rated |
0 |
|
1.07 |
Welding time of 2nd phase | 0~9999 | ||
0 |
||||
1.08 |
Welding para. of 3rd phase | 0~Rated |
0 |
|
1.09 |
Welding time of 3rd phase | 0~9999 |
0 |
|
1.10 |
Welding para. of 4th phase | 0~Rated |
0 |
|
1.11 |
Welding time of 4th phase | 0~9999 |
0 |
|
1.12 |
Welding para. of 5th phase | 0~Rated |
0 |
|
1.13 |
Welding time of 5th phase | 0~9999 |
0 |
|
1.14 |
Welding para. of 6th phase | 0~Rated |
0 |
|
1.15 |
Welding time of 6th phase | 0~9999 |
0 |
|
1.16 |
Cooling time | 0~9999 |
0 |
|
Parameter menu 2: Formula function parameters |
||||
2.01 |
Formula No. | 0~20 |
0 |
R/W |
2.02 |
Formula pipe type | 0~32000 |
0 |
|
2.03 |
Formula pipe resistance | 0.00~19.99 |
0 |
|
2.04 |
Formula control mode | Constant voltage / constant current |
Constant voltage |
|
2.05 |
Formula welding phases | 1~6 |
1 |
|
2.06 |
Welding para. of 1st phase | 0~Rated |
0 |
|
2.07 |
Welding time of 1st phase | 0~9999 |
0 |
|
2.08 |
Welding para. of 2nd phase | 0~Rated |
0 0 |
|
2.09 |
Welding time of 2nd phase | 0~9999 | ||
0 |
||||
2.10 |
Welding para. of 3rd phase | 0~Rated |
0 |
|
2.11 |
Welding time of 3rd phase | 0~9999 |
0 |
|
2.12 |
Welding para. of 4th phase | 0~Rated |
0 |
|
2.13 |
Welding time of 4th phase | 0~9999 |
0 |
|
2.14 |
Welding para. of 5th phase | 0~Rated |
0 |
|
2.15 |
Welding time of 5th phase | 0~9999 |
0 |
|
2.16 |
Welding para. of 6th phase | 0~Rated |
0 |
|
2.17 |
Welding time of 6th phase | 0~9999 |
0 |
|
2.18 |
Formula cooling time | 0~9999 |
0 |
|
2.19 |
Save present formula | 0~1 |
0 |
|
Parameter menu 3: parameters setting |
||||
3.01 |
Standard ambient temperature | 0.0~50.0℃ |
20℃ |
R/W |
3.02 |
Ambient temperature compensation | 0.00%~0.09% |
0.02% |
|
3.03 |
Welding pause enable | 0~1 |
0 |
|
3.04 |
Pipe identification enable | 0~1 |
0 |
|
3.05 |
Doubling voltage setting | 1.0~15.0 |
10.0 |
|
3.06 |
Bar code type setting | 0~1 |
0 |
|
3.07 |
Resistance identification enable | 0~1 |
0 |
|
3.08 |
Resistance range | 0~±30% |
±15% |
|
3.09 |
Language | 0~2 |
0 |
|
3.10 |
Year | 1~99 |
16 |
|
3.11 |
Month | 1~12 |
8 |
|
3.12 |
Day | 1~31 |
8 |
|
3.13 |
Hour | 0~23 |
8 |
|
3.14 |
Minute | 0~59 |
8 |
|
3.15 |
Factory setting | 0~9999 |
1000 |
|
Parameter menu 5: satellite received parameter setting |
||||
5.01 |
Current time zone setting | -12~+12 |
8 |
R/W |
5.02 |
Satellite time update | 0~1 |
0 |
|
5.03 |
Current satellite number | – |
– |
R |
Parameter menu 6: engineering parameter setting |
||||
6.01 |
Engineering No. | Combination of 20 letters and numbers |
– |
R/W |
6.02 |
Project No. | Combination of 20 letters and numbers |
– |
|
6.03 |
Welder No. | Combination of 6 numbers |
– |
|
6.04 |
Welding joint No. | Combination of 6 numbers |
– |
|
6.05 |
Pipe type | Combination of 10 letters and numbers |
– |
|
6.06 |
Pipe fittings factory | Combination of 5 letters and numbers |
– |
|
6.07 |
Pipe diameter | Combination of 5 letters and numbers |
– |
|
6.08 |
Pipe fitting SDR | 33;26;21;17.6;17;13.6;11;9;None |
None |
|
6.09 |
Pipe material | PE80/PE100/ None |
None |
|
6.10 |
Welding machine No. | Combination of 25 letters and numbers |
– |